Language:

LATEX EXAMINATION GLOVE

Type
  • Powdered & Powder-Free, Non-sterile
Material
  • Natural High Grade Rubber Latex
Colour
  • Natural, Blue, Green, Pink, Dark Blue, Black
Flavour
  • Mint, Vanilla
Design & Features
  • Powdered:
    Ambidextrous, smooth or palm textured surface, beaded cuff, USP grade absorbable corn starch
  • Powder-Free:
    Polymer coated, online single chlorinated or offline double chlorinated, ambidextrous, smooth or palm textured surface, beaded cuff
Storage
  • The gloves shall maintain their properties when stored in a dry condition. Avoid direct sunlight
Shelf-life
  • 5 years from the date of manufacturing

Download BrochureSend Enquiry

 


Functional Benefits:

  • Protection from unwanted or dangerous substances
  • Easy donning and helps prevent roll back
  • Softness provides superior comfort and natural fit
  • Beaded cuff makes donning easy
  • Ambidextrous and straight fingers

Quality Standards:

  • Conforms to ASTM D3578 and EN 455 Standards
  • Manufactured under QSR (GMP), ISO 9001:2015 and ISO 13485:2016 Quality Management System
  • Using USP grade absorbable cornstarch for powdered glove

Glove Sizes:

  • Extra-Small, Small, Medium, Large, Extra-Large
  • Size of gloves shall be marked in the check box on the shipping carton with black ink

International Quality System Certificate Awarded:

Dimension Standard
Top Glove ASTM D3578 EN 455
Length (mm) Min 240 Min 220 (XS, S)
Min 230 (M, L)
Min 240
Palm Width (mm)
XS
S
M
L
XL

76 +/- 3
84 +/- 3
94 +/- 3
105 +/- 3
113 +/- 3

70 +/- 10
80 +/- 10
95 +/- 10
111 +/- 10
N/A

≤ 80
80 +/- 10
95 +/- 10
110 +/- 10
≥ 110
Thickness : Single Wall (mm)
Finger
Palm

Min 0.08
Min 0.08

Min 0.08
Min 0.08

N/A
N/A
Property ASTM D3578 EN 455
Tensile Strength (MPa)
Before Aging
After Aging

Min 18
Min 14

N/A
N/A
Elongation at Break (%)
Before Aging
After Aging

Min 650
Min 500

N/A
N/A
Median Force at Break (N)
Before Aging
After Aging

N/A
N/A

Min 6
Min 6

1.1) Biocompatibility Tested

Reference: ISO 10993-10 (Test for Skin Irritation and Skin Sensitization)

Purpose: Biological evaluation for medical devices for irritation and delayed type hypersensitivity

Property Test Results
Primary Skin Irritation
Passes
Not a primary skin irritant under condition of the study
Skin Sensitization
Passes
Not a contact sensitizer under condition of the study


1.2) Viral Penetration Tested

Reference: ASTM F1671 - Standard Test Method for Resistance of Materials Used in Protective Clothing to Penetration by Blood - Borne Pathogens Using Phi-X 174 Bacteriophage Penetration as a Test System

Purpose: To test the barrier protection of the gloves from the passages of the viruses

Viral Penetration Test Results
Passes
Remarks: Applicable to selected products. Please liaise with our representative for further details.


1.3) Heavy Metal Tested

Purpose: To ensure gloves are free from heavy metals substances

Chemical Test (s) Test Results (mg/kg)
Cadmium (Cd) Not Detected
Lead (Pb) Not Detected
Mercury (Hg) Not Detected
Arsenic (As) Not Detected
Antimony (Sb) Not Detected
Tin (Sin) Not Detected
Remarks: Applicable to selected products. Please liaise with our representative for further details.


1.4) Chemical Residue Tested

Purpose: To ensure gloves are free from any chemical substances

Chemical Test (s) Test Results (μg/g)
Butylated Hydroxyanisole (BHA) Not Detected
Butylated Hydroxytoluene (BHT) Not Detected
Mercaptobenzothiazole (MBT) Not Detected
Tetramethylthiuram Disulphide (TMTD) Not Detected
Zinc Dibutyldithiocarbamate (ZDBC) Not Detected
Zinc Diethyldithiocarbamate (ZDEC) Not Detected
Zinc Dimethyldithiocarbamate (ZDMC) Not Detected
Zinc Mercaptobenzimidazole (ZMBI) Not Detected
Zinc Mercaptobenzothiazole (ZMBT) Not Detected
Zinc Pentamethyleneditithiocarbamate (ZPMC) Not Detected
Remarks: Applicable to selected products. Please liaise with our representative for further details.